Welcome to Auto, Motorcycle Parts & Accessories official website!

Cold Water High Pressure Washer Specification Example for Camper Conversions: Vented Design

Source:Diesel Fuel Enhancer / Time:2026-09-18

Cold Water High Pressure Washer Specification Example for Camper Conversions: Vented Design

This is a worked specification for cold water high pressure washer in a vented design programme. It is the document we would send a buyer who asks what exactly they are getting: the material, the dimensions that are actually controlled, the finish, and the checks that happen before anything is packed.

The vented design version exists because the duty cycle on camper conversions is not the same as on a showroom vehicle. Where the two are specified identically, something fails later — usually a supplier who changed material without saying so.

Cold Water High Pressure Washer

Example specification

ItemCold Water High Pressure Washer
ApplicationCamper Conversions
VersionVented Design
Base materialNylon 66
Controlled dimensions5 key dimensions, recorded per lot
Tolerance band±0.1 mm
Finishzinc plated
MOQ3,000 pieces per specification
Sampling14 working days, 5 days per revision
ComplianceECE R90

How the example is built up

  1. Start from the duty cycle, not from the catalogue photograph.
  2. Fix the base material in writing — Nylon 66, in this example.
  3. List the dimensions that are actually controlled and the tolerance on each.
  4. Name the finish and what it has to survive.
  5. State the inspection level and who pays when a lot fails.

Cold Water High Pressure Washer example

Processes involved

  • injection moulding
  • surface grinding
  • sintering
  • assembly line testing
  • ultrasonic cleaning
  • electroplating

Where this example applies

Programmes that run vented design most often specify this build for camper conversions. Related applications include rental motorcycles, city buses, long-haul trucks, aftermarket retail, workshop replacements.

Checks before packing

  • Dimensional report against the approved drawing.
  • AQL 2.5 sampling on the finished lot.
  • Finish inspection under agreed lighting.
  • Carton drop test on the first lot of a new packing specification.

Questions buyers ask

What testing is included?

Standard lots ship with dimensional and hardness reports. ECE R90 documentation is issued with the shipment when your market requires it.

Do you handle mixed containers?

Yes. Most programmes consolidate several part numbers into one container to keep freight sensible at 3000 pieces per line.

How long does sampling take?

Samples leave the factory in 14 working days, and each revision round adds about 5 days once you have seen the first piece.

What happens if a lot fails inspection?

The lot is re-inspected against the golden sample, and replacement pieces ship on the next available booking at our cost.

Send the part number, the annual volume and the target market, and we will come back with a specification and a sampling plan.

Online customer service
WeChat contact
Customer service
Scan code to add Wechat (same mobile phone number)
Telephone consultation
Back to top