Welcome to Auto, Motorcycle Parts & Accessories official website!

Automotive Air Conditioning Specification Example for City Buses: High Performance

Source:Fuel Cooling System / Time:2026-09-18

Automotive Air Conditioning Specification Example for City Buses: High Performance

This is a worked specification for automotive air conditioning in a high performance programme. It is the document we would send a buyer who asks what exactly they are getting: the material, the dimensions that are actually controlled, the finish, and the checks that happen before anything is packed.

The high performance version exists because the duty cycle on city buses is not the same as on a showroom vehicle. Where the two are specified identically, something fails later — usually premature wear on the first batch.

Automotive Air Conditioning

Example specification

ItemAutomotive Air Conditioning
ApplicationCity Buses
VersionHigh Performance
Base materialTempered Glass
Controlled dimensions3 key dimensions, recorded per lot
Tolerance band±0.2 mm
Finishanodised
MOQ1,000 pieces per specification
Sampling10 working days, 3 days per revision
ComplianceSGS

How the example is built up

  1. Start from the duty cycle, not from the catalogue photograph.
  2. Fix the base material in writing — Tempered Glass, in this example.
  3. List the dimensions that are actually controlled and the tolerance on each.
  4. Name the finish and what it has to survive.
  5. State the inspection level and who pays when a lot fails.

Automotive Air Conditioning example

Processes involved

  • injection moulding
  • die casting
  • anodising
  • gravity casting
  • precision stamping
  • CNC machining

Where this example applies

Programmes that run high performance most often specify this build for city buses. Related applications include dealership service, three-wheelers, export programmes, agricultural trailers, camper conversions.

Checks before packing

  • Dimensional report against the approved drawing.
  • AQL 2.5 sampling on the finished lot.
  • Finish inspection under agreed lighting.
  • Carton drop test on the first lot of a new packing specification.

Questions buyers ask

Can the specification be held on file?

Yes. Once approved, the specification is recorded against your part number so a reorder reproduces the SGS-compliant build instead of a fresh interpretation.

What happens if a lot fails inspection?

The lot is re-inspected against the golden sample, and replacement pieces ship on the next available booking at our cost.

What testing is included?

Standard lots ship with dimensional and hardness reports. SGS documentation is issued with the shipment when your market requires it.

What is the minimum order quantity?

The standard MOQ is 1000 pieces per specification. Mixed sizes inside one shipment are accepted once the total reaches that figure.

Share a sample or a drawing and we will quote against a written specification, not against a photograph.

Online customer service
WeChat contact
Customer service
Scan code to add Wechat (same mobile phone number)
Telephone consultation
Back to top