Commercial AC Charging Station Specification Example for Passenger Cars: Adjustable Type
Commercial AC Charging Station Specification Example for Passenger Cars: Adjustable Type
This is a worked specification for commercial ac charging station in a adjustable type programme. It is the document we would send a buyer who asks what exactly they are getting: the material, the dimensions that are actually controlled, the finish, and the checks that happen before anything is packed.
The adjustable type version exists because the duty cycle on passenger cars is not the same as on a showroom vehicle. Where the two are specified identically, something fails later — usually a supplier who changed material without saying so.

Example specification
| Item | Commercial AC Charging Station |
|---|---|
| Application | Passenger Cars |
| Version | Adjustable Type |
| Base material | Polypropylene |
| Controlled dimensions | 5 key dimensions, recorded per lot |
| Tolerance band | ±0.5 mm |
| Finish | as machined |
| MOQ | 200 pieces per specification |
| Sampling | 7 working days, 3 days per revision |
| Compliance | SAE J431 |
How the example is built up
- Start from the duty cycle, not from the catalogue photograph.
- Fix the base material in writing — Polypropylene, in this example.
- List the dimensions that are actually controlled and the tolerance on each.
- Name the finish and what it has to survive.
- State the inspection level and who pays when a lot fails.

Processes involved
- laser cutting
- surface grinding
- injection moulding
- anodising
- shot blasting
- ultrasonic cleaning
Where this example applies
Programmes that run adjustable type most often specify this build for passenger cars. Related applications include assembly programmes, municipal fleets, construction equipment, long-haul trucks, scooter fleets.
Checks before packing
- Dimensional report against the approved drawing.
- AQL 4.0 sampling on the finished lot.
- Finish inspection under agreed lighting.
- Carton drop test on the first lot of a new packing specification.
Questions buyers ask
How is packing specified?
Individual packing, inner box quantity and carton marking are confirmed at quotation stage so the cartons arrive ready for your warehouse.
Do you handle mixed containers?
Yes. Most programmes consolidate several part numbers into one container to keep freight sensible at 200 pieces per line.
What happens if a lot fails inspection?
The lot is re-inspected against the golden sample, and replacement pieces ship on the next available booking at our cost.
Can the specification be held on file?
Yes. Once approved, the specification is recorded against your part number so a reorder reproduces the SAE J431-compliant build instead of a fresh interpretation.
Send the specification you are working to and we will confirm what we can match, what we would change and why.