Welcome to Auto, Motorcycle Parts & Accessories official website!

Commercial AC Charging Station Specification Example for Utility Trailers: Folding Type

Source:Steering Damper / Time:2026-09-18

Commercial AC Charging Station Specification Example for Utility Trailers: Folding Type

This is a worked specification for commercial ac charging station in a folding type programme. It is the document we would send a buyer who asks what exactly they are getting: the material, the dimensions that are actually controlled, the finish, and the checks that happen before anything is packed.

The folding type version exists because the duty cycle on utility trailers is not the same as on a showroom vehicle. Where the two are specified identically, something fails later — usually a fitment that looked right on paper and failed on the bench.

Commercial AC Charging Station

Example specification

ItemCommercial AC Charging Station
ApplicationUtility Trailers
VersionFolding Type
Base materialSintered Metal
Controlled dimensions6 key dimensions, recorded per lot
Tolerance band±0.05 mm
Finishas machined
MOQ200 pieces per specification
Sampling10 working days, 3 days per revision
ComplianceECE R90

How the example is built up

  1. Start from the duty cycle, not from the catalogue photograph.
  2. Fix the base material in writing — Sintered Metal, in this example.
  3. List the dimensions that are actually controlled and the tolerance on each.
  4. Name the finish and what it has to survive.
  5. State the inspection level and who pays when a lot fails.

Commercial AC Charging Station example

Processes involved

  • shot blasting
  • gravity casting
  • robot welding
  • heat treatment
  • sintering
  • rubber vulcanisation

Where this example applies

Programmes that run folding type most often specify this build for utility trailers. Related applications include agricultural trailers, construction equipment, export programmes, aftermarket retail, courier fleets.

Checks before packing

  • Dimensional report against the approved drawing.
  • AQL 2.5 sampling on the finished lot.
  • Finish inspection under agreed lighting.
  • Carton drop test on the first lot of a new packing specification.

Questions buyers ask

What happens if a lot fails inspection?

The lot is re-inspected against the golden sample, and replacement pieces ship on the next available booking at our cost.

What testing is included?

Standard lots ship with dimensional and hardness reports. ECE R90 documentation is issued with the shipment when your market requires it.

How is packing specified?

Individual packing, inner box quantity and carton marking are confirmed at quotation stage so the cartons arrive ready for your warehouse.

Do you handle mixed containers?

Yes. Most programmes consolidate several part numbers into one container to keep freight sensible at 200 pieces per line.

Tell us the model, the fitment and the quantity and we will hold a production slot for you.

Online customer service
WeChat contact
Customer service
Scan code to add Wechat (same mobile phone number)
Telephone consultation
Back to top