Welcome to Auto, Motorcycle Parts & Accessories official website!

Air Conditioning Filter Drier Specification Example for Emergency Vehicles: OEM Replacement

Source:Onboard Diagnostic Tools / Time:2026-09-18

Air Conditioning Filter Drier Specification Example for Emergency Vehicles: OEM Replacement

This is a worked specification for air conditioning filter drier in a oem replacement programme. It is the document we would send a buyer who asks what exactly they are getting: the material, the dimensions that are actually controlled, the finish, and the checks that happen before anything is packed.

The oem replacement version exists because the duty cycle on emergency vehicles is not the same as on a showroom vehicle. Where the two are specified identically, something fails later — usually lead time that slipped twice before bulk started.

Air Conditioning Filter Drier

Example specification

ItemAir Conditioning Filter Drier
ApplicationEmergency Vehicles
VersionOEM Replacement
Base materialSemi-Metallic Compound
Controlled dimensions3 key dimensions, recorded per lot
Tolerance band±0.05 mm
Finishzinc plated
MOQ200 pieces per specification
Sampling7 working days, 3 days per revision
ComplianceISO 9001

How the example is built up

  1. Start from the duty cycle, not from the catalogue photograph.
  2. Fix the base material in writing — Semi-Metallic Compound, in this example.
  3. List the dimensions that are actually controlled and the tolerance on each.
  4. Name the finish and what it has to survive.
  5. State the inspection level and who pays when a lot fails.

Air Conditioning Filter Drier example

Processes involved

  • anodising
  • die casting
  • electroplating
  • rubber vulcanisation
  • injection moulding
  • assembly line testing

Where this example applies

Programmes that run oem replacement most often specify this build for emergency vehicles. Related applications include passenger cars, dealership service, rental motorcycles, municipal fleets, camper conversions.

Checks before packing

  • Dimensional report against the approved drawing.
  • AQL 2.5 sampling on the finished lot.
  • Finish inspection under agreed lighting.
  • Carton drop test on the first lot of a new packing specification.

Questions buyers ask

Can the specification be held on file?

Yes. Once approved, the specification is recorded against your part number so a reorder reproduces the ISO 9001-compliant build instead of a fresh interpretation.

Do you handle mixed containers?

Yes. Most programmes consolidate several part numbers into one container to keep freight sensible at 200 pieces per line.

Can you match an existing sample?

Send a sample and we will reverse-engineer the specification, then produce a counter sample for approval before any bulk starts.

How is packing specified?

Individual packing, inner box quantity and carton marking are confirmed at quotation stage so the cartons arrive ready for your warehouse.

Tell us the model, the fitment and the quantity and we will hold a production slot for you.

Online customer service
WeChat contact
Customer service
Scan code to add Wechat (same mobile phone number)
Telephone consultation
Back to top